Illumination test chamber

Full spectrum sunlight simulation meets gjb150.7-86, gjb150a.7-2009, iec60068-2-5, gjb4.12-83 and other relevant standards

Series:

Full spectrum vehicle

Temperature Range::

-20 ℃ ~ 100 ℃

Cooling Rate:

1 ℃ / min (no load, measured at ambient temperature of 20 ± 2 ℃)

Details

Walk-in full-spectrum sunlight simulation test cabin
Full spectrum sunlight simulation meets gjb150.7-86, gjb150a.7-2009, iec60068-2-5, gjb4.12-83 and other relevant standards
Internal dimension: 8000mm deep × 5000mm wide × 3500mm high
Temperature range: - 30 ℃ ~ + 65 ℃
Humidity range: 20% ~ 95% within the ambient temperature range
Sunlight Simulation (Full Spectrum)
Radiation intensity: 600~1200W/㎡ (adjustable)
Irradiation range: 6000mm x 2200mm
Irradiation uniformity: ± 10%
Meet GJB150.7-86, GJB150A.7-2009, IEC60068-2-5,GJB4.12-83 and other relevant standards
Technical parameters
ModelCH400E-SRCH600E-SRCH1000E-SRCH1500E-SR
Nominal internal volume (liters)400L600L1000L1500L
Performance
Temperature range-20 ℃ ~ 100 ℃
Humidity range (no light)
20% ~ 98% R.H (temperature range: +20 ℃ ~ +80 ℃)
Humidity range (with light)20% ~ 80% R.H (temperature range: +20 ℃ ~ +80 ℃)
Temperature fluctuation± 0.3 ℃
Temperature deviation± 2 ℃
Heating rate (average throughout)2 ℃/min (no load, measured at ambient temperature of 20±2 ℃)
Cooling rate (average throughout)1 ℃/min (no load, measured at 20±2 ℃ ambient temperature)
irradiation intensity200~1200W/㎡
spectral distributionComplies with DIN75220 and GJB150.7A
Irradiation area (cm21600330056005600
Internal dimensions (mm)
D70075010001000
W70085010001000
H85090010001500
External dimensions (including height of luminaire)(mm)
D1780180020502360
W950110012501250
H2410249025902590
CasterStandard casters 4
Viewing window430x 430 with heating device to prevent condensation and frost
Test holeRight side of 1 Ø80 box2 Ø100, 1 on the left and right sides of the box
Stainless steel shelf (2 standard)Bearing 25 kg/block
Lighting1*35W/12V
Cooling modeAir cooling (water cooling method can be selected, water cooling (water temperature 7~28 ℃, water pressure 0.2~0.4Mpa)
Power380V ± 10%/50HZ ± 1, three-phase five-wire system (3P + N + G)
Installed capacity (kw)101217.521
Meet the test method
GJB150.7A、MIL-STD 810G、DIN 75220、GB 2423.24 lEC60068-2-5
Safety protection measuresPower supply undervoltage, overvoltage, phase loss, phase sequence error protection; Triple overtemperature protection; Heater short circuit protection; Refrigerator overpressure/overload protection; Humidifier fault protection; Blower motor overload/overheat protection; Control board overcurrent protection; Leakage protection; Light source protection; Timer.
OptionalBlack label thermometer, blackboard thermometer, internet function, etc

 

Previous

Next

Previous

Next

Other Products

High and low temperature damp heat test chamber

CH Series

Temperature range:

150 ℃ ~ -40 ℃ or -70 ℃

Cooling rate:

1 ℃/min or 3 ℃/min

High and low temperature damp heat test chamber

SU Series

Temperature range:

150 ℃ ~ -40 ℃ or -70 ℃

Cooling rate:

1 ℃/min or 3 ℃/min

Rapid temperature change test chamber

Temperature range:

-70 ° ℃ ~ 150 ° ℃

Cooling rate:

5 ℃ ~ 25 ℃ / min (mechanical refrigeration)

Temperature shock test chamber

Hatchback Basket

Temperature range:

-65 ℃ ~ 150 ℃

Cooling rate:

H type is about 4 ℃ / min, M type is about 3 ℃ / min, L type is about 2 ℃ / min (- no-load average value in the range of 55 ° C

Temperature shock test chamber2

Three-compartment

Temperature range:

-65 ℃ ~ 150 ℃

Cooling rate:

H type is about 4 ℃ / min, M type is about 3 ℃ / min, L type is about 2 ℃ / min (- no-load average value in the range of 55 ° C

Temperature and humidity vibration three comprehensive test chamber

Three comprehensive test box

Temperature range:

-70 ℃ ~ 150 ℃

Cooling rate:

1 ℃ - 5 ℃ / min optional (no load, whole process average. - 40 - + 100 ℃)