ATEC

Products
+
  • 14.png
  • 15.png
  • 514所瞬爆减压箱.png
  • QQ图片20181130101430.png

Low pressure and plateau simulation test chamber

TD and UD series are aimed at the adaptability test of equipment or equipment in the aerospace field under the combined action of altitude, temperature and humidity in the air or at high altitude.

Temperature Range::

The suffix without "C" is - 40 ℃ ~ + 150 ℃, and the suffix with "C" - 70 ℃ ~ + 150 ℃

Cooling Rate:

1℃/min

Details

TD and UD series are aimed at the adaptability test of equipment or equipment in the aerospace field under the combined action of altitude, temperature and humidity in the air or at high altitude.

This series of products can meet the comprehensive tests of damp heat, air pressure and temperature, and can be equipped with rapid pressure reduction function. It meets the rapid pressure reduction standard of 75.2kpa ~ 18.8kpa ≤ 15s in gjb150.2a-2009, can also meet the explosion pressure reduction test of 0.1s, and can also be equipped with rapid cooling function and vibration function. We provide 250L, 500L, 1000L and 2000L standard volume series products, and can customize non-standard volume and walk-in products according to customer needs.

Model description

TD product serial number

1000 working room volume (unit: l)

C is the minimum temperature

C: -70℃; None: minimum 40 ℃

technical parameter

ModelTD/UD250 (C)TD/UD500 (C)TD/UD1000 (C)TD/UD2000 (C)
Nominal internal volume (L)250L500L1000L2000L
Performance
Temperature rangeThe suffix without "C" is - 40 ℃ ~ + 150 ℃, and the suffix with "C" - 70 ℃ ~ + 150 ℃
Humidity range20% ~ 98%R.H (Under normal pressure, the humidity working range is + 20 ℃ ~ + 85 ℃. See the temperature and humidity range diagram for details)
Humidity deviation-3~+2%RH(Above 75% RH),±5%RH(Below 75% RH)
Temperature fluctuation±0.3℃ (under normal pressure)
Temperature deviation±2℃(under normal pressure)
Heating rate (whole process average)2℃/min2℃/min2℃/min2℃/min
Cooling rate (whole process average)1℃/min1℃/min1℃/min1℃/min
RemarksThe above indexes are measured under no-load and normal pressure, in which the temperature rise and fall rate is measured at + 85 / - 30 ℃ and + 85 / - 55 ℃
Pressure rangeRoom pressure ~ 0.5kpa
Barometric error+2KPa (≥40kPa),+5%(2KPa ~ 40kPa),+0.1KPa(≤2kPa)
Depressurization timeAtmospheric pressure ~ 1kPa, about 30min
Pressure recovery time≤10kPa/min
Internal dimensions(mm)D*W*H500*700*750700*800*9001000*1000*10001400*1200*1200
External dimensions(mm)D*W*H2250*1170*20002700*1270*21003100*1470*23103600*1670*2600
Observation window300x300
Test hole1DN1002DN100
Stainless steel shelf (2 pieces as standard)Bearing capacity: 20kg / pieceBearing capacity: 50kg / piece
lighting35W/12V2个35W/12V
Operating ambient temperature5 ~ 35℃(The temperature rise and fall rate is measured at the ambient temperature of 20 + 2 ℃)
Cooling modeWater cooling (water temperature 7 ~ 28 ℃, water pressure 0.2 ~ 0.4MPa)
Gas sourceCompressed air 0.4 ~ 0.8MPa
Power Supply380V+ 10%/50HZ+1,Three phase five wire system(3P+N+G)
Installed capacity(kw) (C)15/1820/2530/3636/45
Meet the test methodGB2423.1,GB2423.2,GB2423.21, GJB150.3, GJB150.4, GJB150.2 (Except rapid depressurization),GJB150.6, GB/T 2423.27 Test Z / AMD low temperature / low pressure / damp heat continuous synthesis, gjb150.19-86 temperature humidity height, GJB 150.24a temperature humidity vibration height (except vibration)
Safety protection measuresPower supply undervoltage, overvoltage, phase loss and phase sequence error protection; Triple overtemperature protection; Heater short circuit protection; Refrigerator overpressure / overload protection; Overload / overheating protection of blower motor; Control board overcurrent protection; Leakage protection; Overload protection of vacuum pump; Compressed air undervoltage protection.
OptionalSpecial test hole, aviation plug, terminal, special shelf, etc. can be equipped with 15s rapid decompression, 0.1s explosion decompression, vibration function, etc.
 

Previous

Next

Previous

Next

Other Products

High and low temperature damp heat test chamber

CH Series

Temperature range:

150 ℃ ~ -40 ℃ or -70 ℃

Cooling rate:

1 ℃/min or 3 ℃/min

High and low temperature damp heat test chamber

SU Series

Temperature range:

150 ℃ ~ -40 ℃ or -70 ℃

Cooling rate:

1 ℃/min or 3 ℃/min

Rapid temperature change test chamber

Temperature range:

-70 ° ℃ ~ 150 ° ℃

Cooling rate:

5 ℃ ~ 25 ℃ / min (mechanical refrigeration)

Temperature shock test chamber

Hatchback Basket

Temperature range:

-65 ℃ ~ 150 ℃

Cooling rate:

H type is about 4 ℃ / min, M type is about 3 ℃ / min, L type is about 2 ℃ / min (- no-load average value in the range of 55 ° C

Temperature shock test chamber2

Three-compartment

Temperature range:

-65 ℃ ~ 150 ℃

Cooling rate:

H type is about 4 ℃ / min, M type is about 3 ℃ / min, L type is about 2 ℃ / min (- no-load average value in the range of 55 ° C

Temperature and humidity vibration three comprehensive test chamber

Three comprehensive test box

Temperature range:

-70 ℃ ~ 150 ℃

Cooling rate:

1 ℃ - 5 ℃ / min optional (no load, whole process average. - 40 - + 100 ℃)

I want to consult