ATEC

News Center

Walk-in full-spectrum sunlight simulation test cabin

2021-08-11

Full spectrum sunlight simulation, meeting relevant standards such as GJB150.7-86, GJB150A.7-2009,IEC60068-2-5,GJB4.12-83, etc. Internal dimensions: depth 8000mm × width 5000mm × height 3500mm temperature range:-30 ℃ ~ +65 ℃ humidity range: 20% ~ 95% sunlight simulation in ambient temperature range: (full spectrum) radiation intensity: 600~1200W/㎡ (adjustable) irradiation range: 6000mm x 2200mm irradiation uniformity: 10%

Walk-in battery pack test box

2021-08-11

The active protection and passive protection of the test chamber have multiple unique protection designs, which can prevent and reduce the leakage, explosion and other accidents that may occur during the development of the battery. Main indicators Temperature range:-50 ℃ ~ +120 ℃ Temperature rise and fall rate: 1~5 ℃/min (optional) Humidity range: 10% ~ 98% RH;(Meet the test requirements of GBT31467.3-2015) Meet the standards GB/T31467.3-2015, GB/T31485-2015 GB/T2423.1-2008

National military standard sand and dust test chamber

2021-08-11

The test chamber consists of the following parts: test chamber body, blowing system, heating and cooling air conditioning system, drying and dehumidification system, powder/sand dust recovery and feeding system, sample turntable system, power distribution and control system. Main Indicators Blowing Section: 1000 × 1000(W×H)mm Temperature Range: RT ~ 60 ℃ Humidity Range: ≤ 30% RH Time Range: 1~99 h59m59s (Adjustable) Sand Blowing Test Sand Diameter: 150um≥ Particle Diameter Sand Blowing Concentration: 10.6±7 g/m Wind Speed 1.5~8.9 m/s

Rapid temperature change three comprehensive test chamber (damp heat, with vertical vibration table)

2021-08-11

Temperature range:-70 ℃ ~ +150 ℃ temperature uniformity: ≤ 2 ℃ temperature fluctuation: ≤ 0.5 ℃ temperature deviation: ≤ 2 ℃ temperature rise/drop rate: (fast change temperature range:-55 ℃ ~ 125 ℃) linear rise/drop rate: ≥ 5 ℃/min, load 1T aluminum block, 10kw heating nonlinear rise/drop rate: ≥ 5 ℃/min, load 1.8T aluminum block, 23kw heating no-load rise/drop average temperature change rate: ≥ 15 ℃/min humidity range: 15% to 98% r. h.

Four-pillar tire coupling road simulation environmental chamber (with sunlight simulation)

2021-08-10

This equipment has a large adjustment range of vehicle wheelbase and wheelbase, and adopts automatic adjustment, which is convenient and quick, and improves equipment operation efficiency. The cover plate of this equipment is made of heat insulation material, which has better heat insulation effect. The cover plate is moved by automatic device, which is more convenient.

Infrared vehicle environmental test chamber (a unit in Nanchang)

2021-08-10

This vehicle cold start environmental chamber is used for the performance test of electric vehicles with motor power ≤ 150kW, providing environmental simulation conditions with temperature of -20 ℃ ~ +60 ℃. Technical specifications: temperature control range:-20 ℃ ~ +60 ℃ humidity range: relative humidity: 30 ~ 95% infrared radiation lamp: maximum 1200±25W/m2, uniformity 10% adjustment range: 30% ~ 100 when there is no light, humidity control is 30% ~ 95%; There is no condensation in the cabin during the low temperature test with light humidity control of 30%-80%.

Vehicle comprehensive performance environmental test chamber (hub infrared sunlight simulation) (a unit in Shandong)

2021-08-10

The environmental chamber is mainly used for vehicle high and low temperature storage test, vehicle defrosting, defogging performance test, vehicle cold start performance test, vehicle heating and cooling performance test, vehicle thermal balance test, high and low temperature resistance test of parts, etc. The product is mainly composed of the main body of the climate simulation laboratory, the temperature rise and fall device, the fresh air/tail exhaust system, the sunlight simulation system, the temperature acquisition system in the warehouse, and the electrical control system. The use of cascade screw compressor unit distributed IO control system application equipment reliability to improve the service life of the compressor to extend the power balance, energy saving and environmental protection control system more flexible and reliable.

ATEC ice water impact test chamber

2021-08-10

Ice water impact test (temperature impact test of surge water) is to simulate the load situation of surge water generated when the components are driven through the accumulated water, so as to ensure the functional stability of the components under the condition of rapid cooling due to water. If the vehicle is driving on a watery road in winter, ice water splashes onto a hot system/component, the failure mode is mechanical rupture of the material or seal failure due to different temperature expansion coefficients. (This test is not a corrosion test) Reference standard ISO16750-4-2010 road vehicles. Environmental conditions and test VW80000 for electrical and electronic equipment: 2009 Volkswagen electrical and electronic components

Walk-in compound salt spray test chamber (stainless steel box)

2021-08-10

Walk-in composite salt spray box, meeting GJB150.11A-2009 military equipment laboratory environmental test methods part 11: salt spray test; GB/T10125-1997 artificial atmosphere corrosion test salt spray test and other internal volume: 40m ³ internal dimension: 5000mm × 4000mm × 2000mm (depth, width and height) temperature range:-20 ℃ ~ +60 ℃ controllable humidity range: 10% ~ 98% r. h. salt spray settlement: salt spray settlement can be adjusted from 1 ml/h to 3ml/80c ㎡ h to meet GJB15

Hydrogen fuel cell explosion-proof plateau climate chamber (an inspection institute in Shanghai)

2021-08-06

The equipment is equipped with the air discharge pipeline pressure control system of the new energy engine system (the control range is normal pressure ~ 60KPa, the control accuracy is 2KPa, the maximum emission is about 308 g/S (about 924 m/h)), and the hydrogen discharge pipeline pressure control system (the control range is normal pressure ~ 60KPa, the control accuracy is 2KPa, and the maximum emission is about 80 g/min (about 5.3 m/h))). Main parameters Equipment size: 5500 × 1938 × 2000mm(D * W * H. Internal volume 22m) Temperature range:-45 ℃ ~ 100 ℃ Air pressure

Special test chamber for hydrogen fuel cell (a unit in Dalian)

2021-08-06

The test chamber active protection and passive protection has multiple unique protection design, can prevent and reduce the battery in the development process may produce leakage, explosion and other accidents. Main indicators Temperature range:-50 ℃ ~ +120 ℃ Temperature rise and fall rate: 1~5 ℃/min (optional) Humidity range: 10% ~ 98% RH;(Meet the test requirements of GBT31467.3-2015) Meet the standards GB/T31467.3-2015, GB/T31485-2015 GB/T2423.1-2008,

Military Standard Rain Test Chamber (A Research Institute of AVIC)

2021-08-06

The test chamber conforms to the standard GJB150.8A-2009, which is used for military equipment or electronic products to simulate dynamic operation under various intensity rain environment, and the rain test method and main parameters of military equipment. Rain test, dripping rain test and strengthening test can be realized in one test chamber. Rainfall and rain blowing test parameters Rainfall intensity: 10~20 cm/h Wind speed: 5 m/s ~ 20 m/s Raindrop diameter: 0.5-4.5mm Test time: continuous test ≥ 30min, adjustable set raindrop speed: about 9 m/s Enhanced rain test parameters Spray
< 1234...8 > proceed page